FieldSENSE Designed for Waterproofers’ RF safety

Waterproofing often takes place on the roofs of buildings. On some of these roofs, there will be mobile phone base stations which emit radiation, along with other potential sources of radiation. Now, imagine knowing exactly how much RF you’re getting exposed to on the job in real time.
With the fieldSENSE RF monitor, that’s exactly what you’ll get. It is designed specifically for Waterproofers, like you. It’s lightweight, portable and easy to use, so you can take it with you wherever you go on the job. With a fieldSENSE you’ll always know exactly how much RF exposure you’re getting and be able to take the necessary precautions to protect yourself.

Find out where to order fieldSENSE monitors

Find a distributor
Please give us a call on  (312) 260-6055 or visit any of our direct suppliers below.
fieldSENSE60

Recommended retail price: USD 799

The fieldSENSE60, with extended frequency range, is specifically designed for people whose work takes them near transmitting antennas. This means you can work with confidence in the near-field of a broadcast system or in the far-field of a 5G mmWave system. Exposure is accurately assessed, and a warning is sounded, should the levels approach and exceed the occupational limits.

  • Frequency: 50 MHz to 60 GHz
  • Usage: From FM radio, terrestrial television up to mmWave 5G and beyond
  • Shaped Frequency response (E- & H-fields)
  • Two-year calibration interval
  • Two-year warranty included
 
A graphic showing the frequency spectrum that is assessed by fieldSENSE personal RF monitors
fieldSENSE 2.0

Recommended retail price: USD 599

The fieldSENSE 2.0 has a proven track record of ensuring on-site employee safety. The frequency range covers all typical television and FM radio broadcast services and legacy mobile telecommunications services, amongst others. Exposure is accurately assessed, and a warning is sounded, should the levels approach and exceed the occupational limits.
  • Frequency: 50 MHz to 6 GHz
  • Usage: FM broadcast systems, mobile telecommunications (excl. mmWave)
  • Shaped Frequency response (E- & H-fields)
  • Two-year calibration interval
  • Two-year warranty included

Product Specifications

fieldSENSE60
Frequency coverage
50 MHz – 60 GHz
Recommended retail price
USD 799
Usage
Full spectrum: FM through to mmWave 5G
Frequency response
Shaped (Occupational / Controlled)
Frequency response to
ICNIRP (2020), FCC [NCRP] OET65 (1997), EU Directive 2013/35/EU, Canada Safety Code 6 (2015)
Sensor polarization
Spherical dual polarised Isotropic (± 3 dB < 6 GHz)
Probes
Electric (E-) and Magnetic (H-) field – 3x orthogonal axis isotropic
Data logging
E-field, H-field, Maximum, 6-min average of Maximum & audio
Voice notes
Yes
Fall detection alarm
Yes – 3-axis accelerometer
Calibration interval
Recommended two-yearly calibration
Support
Calibration & refurbishment
Batteries
2x AAA (LR03) Alkaline batteries & 2x spare batteries
Harness attachment
Harness clip with coiled lanyard
Elastomer strap and wrist strap
Dimensions
146 x 26 x 42 mm | 5.7 x 1 x 1.7 inches
Weight (incl. batteries)
115 g | 0.25 lb
fieldSENSE 2.0
Frequency coverage
50 MHz – 6 GHz
Recommended retail price
USD 599
Usage
FM, television through to mid band 5G
Frequency response
Shaped (Occupational / Controlled)
Frequency response to
ICNIRP (2020), FCC [NCRP] OET65 (1997), EU Directive 2013/35/EU, Canada Safety Code 6 (2015)
Sensor polarization
Spherical dual polarised Isotropic (± 3 dB < 6 GHz)
Probes
Electric (E-) and Magnetic (H-) field – 3x orthogonal axis isotropic
Data logging
E-field, H-field, Maximum, 6-min average of Maximum & audio
Voice notes
Yes
Fall detection alarm
Yes – 3-axis accelerometer
Calibration interval
Recommended two-yearly calibration
Support
Calibration & refurbishment
Batteries
2x AAA (LR03) Alkaline batteries & 2x spare batteries
Harness attachment
Elastomer strap and wrist strap
Dimensions
146 x 26 x 42 mm | 5.7 x 1 x 1.7 inches
Weight (incl. batteries)
115 g | 0.25 lb
Product Overview Videos
Play Video
FieldSENSE – A Brief History
Play Video
fieldSENSE60 Personal RF Monitor – Overview
Play Video
fieldSENSE 2.0 Personal RF Monitor – Overview
Instructional Videos
Play Video
How to take voice notes
Play Video
Software demonstration
Play Video
How the fieldSENSE60 works
Play Video
How the refurbishment program works
Play Video
How to start using your fieldSENSE
Play Video
How to use the harness attachments
Frequently Asked Questions
Play Video
Who needs RF anyway?
Play Video
Action at a distance
Play Video
What is RF?
Play Video
The characteristics of RF
Play Video
Is too much of a good thing, bad?
Play Video
Who is at risk of overexposure?
Isotropic
FieldSENSE personal RF monitors each have a total of six orthogonal E- and H-field probes to ensure that the combination of all sources of radiation from all angles are correctly measured and assessed in accordance with safety limits.
E- & H-fields Measured
RF Safety guidelines use the radiated power density, S in milliWatt/cm2 or Watt/m2, to assess exposure to electromagnetic fields in a given situation. This is derived from the measured E- (electric) and H- (magnetic) fields. To accurately assess a given exposure situation, both of these should be measured, especially when working very low in frequency around FM transmitters for instance. Only measuring E-field in these instances can lead to inadvertent RF overexposure.
Data Logging
The monitors have an advanced E- and H-field data logger, which records all user measurements so that they can be easily accessed over a USB connection to a PC in the office. Additionally, the data can be viewed in real-time over the USB connection with the PC application.
Voice Notes
The inbuilt logging feature allows for quick voice note taking, which can be accessed later in the office. The data is paired with the logged E- and H-fields so specific exposure conditions can easily be tagged.
Shaped Response
The exposure limits, such as the FCC (NCRP), SC6 or ICNIRP limits, are all shaped over frequency. As such, PPE must also have a shaped probe response to accurately measure in accordance with it. RF monitors without a shaped response are inaccurate and can result in an individual being overexposed.
Fall-detection & Alarm
The devices have an inbuilt fall detection system which sounds an alarm should the user accidentally fall. The alarm is easily silenced should the user still be conscious but, should they have been knocked unconscious the sounding alarm will attract the attention of colleagues. This way they are able to immediately initiate rescue actions thus reducing the potential effects of suspension trauma following a fall at height.
Product Features
Isotropic
FieldSENSE personal RF monitors each have a total of six orthogonal E- and H-field probes to ensure that the combination of all sources of radiation from all angles are correctly measured and assessed in accordance with safety limits.
E- & H-fields Measured
RF Safety guidelines use the radiated power density, S in milliWatt/cm2 or Watt/m2, to assess exposure to electromagnetic fields in a given situation. This is derived from the measured E- (electric) and H- (magnetic) fields. To accurately assess a given exposure situation, both of these should be measured, especially when working very low in frequency around FM transmitters for instance. Only measuring E-field in these instances can lead to inadvertent RF overexposure.
Data Logging
The monitors have an advanced E- and H-field data logger, which records all user measurements so that they can be easily accessed over a USB connection to a PC in the office. Additionally, the data can be viewed in real-time over the USB connection with the PC application.
Voice Notes
The inbuilt logging feature allows for quick voice note taking, which can be accessed later in the office. The data is paired with the logged E- and H-fields so specific exposure conditions can easily be tagged.
Shaped Response
The exposure limits, such as the FCC (NCRP), SC6 or ICNIRP limits, are all shaped over frequency. As such, PPE must also have a shaped probe response to accurately measure in accordance with it. RF monitors without a shaped response are inaccurate and can result in an individual being overexposed.
Fall-detection & Alarm
The devices have an inbuilt fall detection system which sounds an alarm should the user accidentally fall. The alarm is easily silenced should the user still be conscious but, should they have been knocked unconscious the sounding alarm will attract the attention of colleagues. This way they are able to immediately initiate rescue actions thus reducing the potential effects of suspension trauma following a fall at height.
User Interface
FieldSENSE devices use high brightness amber LED indicators for direct sunlight visibility and have a loud buzzer to ensure the user won’t miss a thing. Additionally, it is specifically designed to be operated whilst wearing gloves.
Attachments
Devices come with an easily adjustable wrist strap to ensure comfortable attachment while working. Additionally, the fieldSENSE60 harness attachment mechanism has been completely redesigned to include a coiled lanyard system. This facilitates the smooth handling of the device during operations while still remaining visible and audible. Should the device be dropped there is no risk of it falling off the site. A tripod attachment point on the base of the device allows for setting up remote monitoring of a site, or for attaching an extension pole.
AAA batteries
The devices use readily available AAA (LR03) batteries.
“Grippy” design
The device has a custom bevelled design that fits tightly into the user’s hand with a textured soft elastomer surface and grip ridges ensuring no fumble moments.
Rugged IP64 & IK08 Enclosure
The devices have a co-moulded enclosure with a base layer of polycarbonate which is typically used in riot shields, and an outer elastomer layer made of TPU which is designed for hard wearing environments. The design provides for IP64 dust & moisture ingress rating as well as IK08 impact protection.
Zipper Case
Shipped in a heavy-duty zipper case with a custom moulded insert makes for even further protection of the device.
Brochures & Policy Documents
Guides
Software Downloads
Find a distributor
Please give us a call on  (312) 260-6055 or visit any of our direct suppliers below.

Add Your Heading Text Here